Microbiology

EXS 3000

Mass Spectrometry System(MALDI-TOF)

Fast and accurate,
the powerful
assistant for laboratory

Proprietary intellectual property rights /
High throughput /
Easy operation / Low cost

Mass Spectrometry System(MALDI-TOF)

Excellent performance

Distinctive circuit design with dust-free air duct to improve signal-to-noise ratio and reduce fault rate

3G Hz spsSampling frequency up to 3GHz sps

Sampling frequency up to 3GHz sps
Ion repulsion module: Apply intelligent repulsion technology to eliminate the interfering ions and increase the life of the detector
High-precision delayed extraction technology reducing ion jitter and improving mass accuracy

  • Distinctive circuit design
    with dust-free air duct
  • Ion repulsion module
  • High-precision delayed extraction technology

Negative ion module supporting both positive
and negative ion mode detection and
increasing
sample detection limit

4000+4000+ strains, including clinical and scientific
research microorganisms

Accurate identification, user-friendly operation

Support offline database, which covers clinical and scientific
research microorganisms. Cover 4000+ strains,
including Mycobacterium, Filamentous fungus,
Anaerobic bacteria, Nocardia, Legionella, Shewanella,
and Highly pathogenic bacteria, etc.

Support offline database, which covers clinical and scientific research microorganisms. Cover 4000+ strains, including Mycobacterium,
Filamentous fungus, Anaerobic bacteria, Nocardia, Legionella, Shewanella, and Highly pathogenic bacteria, etc.

Easy software operation

The easy operating system synchronizes the collection and search functions. It provides strain identification results in English while giving the
morphological information simultaneously, supports the data connection with the LIS system to improve the efficiency of clinical detection.

Use silent molecular pump to reduce environmental noise and improve working environment of laboratory

Wide application, the powerful assistant for laboratory

Instrument supports nucleic acid detection research by mass spectrometry (such as research on deafness gene)
Negative ion mode helps to establish more rapid antimicrobial susceptibility testing programs,
carry out phosphorylated protein detection and research on the typing of some difficult-to-identify bacteria.

  • Support nucleic acid research and detection by mass spectrometry
  • Negative ion mode

Typing research on microorganism siblings and their subspecies Such as the toxigenic and non-toxigenic strain of Clostridium difficile, differentiation between Escherichia coli and Shigella, etc.

Equipped with Principal Component Analysis (PCA) and other spectrum analysis functions, it can be used for clinical research such as antimicrobial susceptibility testing, serogroup typing, retrospective analysis of strains and identification of intractable funguses.

  • Principal Component
    Analysis
    PCA Principal Component Analysis
  • Principal Component
    Analysis
    PCoA, Principal Coordinate Analysis
  • t-distributed Stochastic Neighbor
    Embedding
    t-SNE, t-Distributed Stochastic Neighbor Embedding

Setosa

versicolor

Special matrix and matching kit for Mass Spectrometry System

Blood Culture Positive Sample Pretreatment reagent, which supports the direct identification of blood culture positive samples on instrument to shorten the reporting time and meet the needs of rapid clinical diagnosis

Blood Culture Positive Sample Pretreatment Kit for Mass Spectrometry System

Mold Sample Pretreatment Kit for Mass Spectrometry System provides mold solutions with over 300 species of filamentous fungi database, the operation only takes 2 minutes

Mold Sample Pretreatment Kit for Mass Spectrometry System

Ready-to-use Sample processing Matrix Solution for Mass Spectrometry System with good crystallization effect. No need to refrigerate. Stability, convenience and high speed.

Sample processing Matrix Solution for Mass Spectrometry System

Mold Sample Pretreatment Kit for Mass Spectrometry System provides mold solutions with over 300 species of filamentous fungi database, the operation only takes 2 minutes

Microbe Sample Pretreatment Kit for Mass Spectrometry System

Special matrix and matching kit for Mass Spectrometry System

  • Blood Culture Positive Sample Pretreatment Kit for Mass Spectrometry System

    Blood Culture Positive Sample Pretreatment reagent, which supports the direct identification of blood culture positive samples on instrument to shorten the reporting time and meet the needs of rapid clinical diagnosis

  • Mold Sample Pretreatment Kit for Mass Spectrometry System

    Mold Sample Pretreatment Kit for Mass Spectrometry System provides mold solutions with over 300 species of filamentous fungi database, the operation only takes 2 minutes

  • Sample processing Matrix Solution for Mass Spectrometry System

    Ready-to-use Sample processing Matrix Solution for Mass Spectrometry System with good crystallization effect. No need to refrigerate. Stability, convenience and high speed.

  • Microbe Sample Pretreatment Kit for Mass Spectrometry System

    Mold Sample Pretreatment Kit for Mass Spectrometry System provides mold solutions with over 300 species of filamentous fungi database, the operation only takes 2 minutes

Patient blood culture specimen
Positive blood culture specimen
Direct identification on EXS3000
Rapid clinical diagnosis
Direct identification on EXS3000

EXS3000 system

  • windowsOperating system: windows system, identification results in English, connection with LIS system
  • Dimension800mm×490mm×1215mm Depth X width X height
  • Weight116.1 KG
  • Power Requirement~220 V±22 V,50 Hz±1 Hz